1) The total amount of fixed charge current: 10A
2) the total rated load current: 10A
3) overload, short circuit protection
4) 1.25 times the rated current of 60 seconds, 1.5 times the rated current of 5 seconds, overload protection action, ≥ 3 times the rated current short circuit protection
5) No-load loss: ≤ 5mA
6) Charging circuit voltage drop: less than 0.26V
7) The discharge circuit voltage drop: less than 0.15V
8) Over voltage protection: 17V; × 2/24V
9) Operating temperature: Industrial; -35 ℃ to 55 ℃ (suffix I)
10) to enhance the charging voltage: 14.6V; × 2/24V; (duration: 10min) (discharge only if there have been calls)
11) Direct charge voltage: 14.4V; × 2/24V; (duration: 10min)
12) Float: 13.6V; × 2/24V; (duration: up down charge return voltage operation)
13) Charge back voltage: 13.2V; × 2/24V
14) Temperature compensation:-5mv / ℃ / 2V (upgrade, direct charge, floating charge, charge back voltage compensation)
15) Brown-out Voltage: 12.0V; × 2/24V
16) over-discharge voltage: 11.1V-discharge rate of compensation fixed initial over-discharge voltage (load voltage); × 2/24V
17) had put back power: voltage 12.6V; × 2/24V
18) Control mode: charge transfers for the PWM pulse width
19) Dimensions: 140 × 90.5 (mm)
20) Installation hole size: 133.5 × 70 (mm)